Enjoy 20% off your first order · use code Free shipping on orders $100+ · free 2-Day $175+Ships today when you order before 3 PM ET

ISO/IEC 17025

(“EYE-soh one-seven-oh-two-five”)

The standard that separates a lab that runs tests from a lab proven to run them well.

The short answer

ISO/IEC 17025 is the international standard that sets out what a testing or calibration laboratory must do to show it is competent and produces valid results.

Labs are accredited to it by an accreditation body that audits their methods, equipment, staff, records and reporting. The accreditation covers only the specific methods listed on the lab’s scope, so the useful question is never just whether a lab is accredited, but whether the test you care about is on its scope.

Reviewed by the Codex Research quality teamUpdated Nov 8, 2026

Word study

The word itself

Say it

I·S·O / I·E·C 17·025

(“EYE-soh one-seven-oh-two-five”)

Part of speech
Noun (standard name)
Syllables
9
Abbreviation
ISO 17025; current edition ISO/IEC 17025:2017

Roots and origin

RootGreek

ISO
From
ísos
Means
equal
isosequal+standarda fixed measure
+

OriginLatin

accreditation
From
accrēditāre
Means
to give credit to
adto+crēdereto believe, trust

ISO is not an acronym: the organization took its short name from the Greek isos, equal, so it would read the same in every language. Accreditation comes from the Latin for giving credit, being believed. An ISO/IEC 17025 accreditation is a formal statement that a lab’s results can be trusted equally, wherever they are read.

Around the world

Tap a language to hear it spoken

Definition

What is ISO/IEC 17025?

ISO/IEC 17025 is published jointly by the International Organization for Standardization and the International Electrotechnical Commission, and its current edition dates from 2017. It sets out the general requirements for the competence of testing and calibration laboratories: what a lab must have in place for its results to be considered valid. It is the standard behind most formal laboratory accreditation worldwide.

The requirements cover the whole operation. A lab must be impartial and keep results confidential. Its staff must be competent for the tests they run, and its equipment must be calibrated with measurements traceable to recognized standards. Its methods must be validated or verified, its results must account for measurement uncertainty, and it must take part in proficiency testing or other comparisons that show its results stay accurate over time.

Labs do not certify themselves. They are accredited by an accreditation body, an organization that assesses the lab against the standard and then keeps auditing it. In the United States these include NIST’s National Voluntary Laboratory Accreditation Program and private accreditation bodies. Bodies that have passed peer evaluation sign the ILAC Mutual Recognition Arrangement, so an accreditation from one signatory is recognized by the others.

The single most important detail is the scope of accreditation. A lab is accredited for specific tests, on specific types of samples, using specific methods, and those are listed on a scope document. A lab accredited for, say, heavy metals in water is not accredited for peptide purity by HPLC unless that method is on its scope. Reading the scope is how you know whether the accreditation applies to the result in front of you.

Wording matters too. Labs are accredited, not certified, to ISO/IEC 17025; certification is the term for management-system standards such as ISO 9001. A lab that says it operates in accordance with ISO/IEC 17025 but names no accreditation body and no certificate number is describing its intentions, not an independent assessment.

Not the same

Accreditation, certification and compliance

17025
Competence, audited

ISO/IEC 17025 accreditation

An accreditation body has assessed the lab’s technical competence for the specific methods on its scope, and keeps auditing it.

9001
Process, not results

ISO 9001 certification

Certifies a quality management system. It says processes are documented and followed, not that test results are technically valid.

Claim
Self-declared

“Operates per ISO 17025”

A lab says it follows the standard but has not been independently assessed. A statement of intent, not accreditation.

GxP
Regulatory

GMP and GLP

Regulatory systems for drug manufacturing and for safety studies. Related to quality, but separate from lab accreditation.

The standard

What an accreditation audit looks at

ISO/IEC 17025 has general, structural, resource, process and management requirements. These are the ones that matter most to someone reading a result.

RequirementWhat it meansWhy it matters
ImpartialityResults are free from commercial or financial pressureThe basis of trusting an independent result.
Personnel competenceStaff are trained and authorized for each testA method is only as good as the person running it.
Metrological traceabilityMeasurements trace back to recognized reference standardsMakes results comparable between labs.
Method validationMethods are shown to be fit for their purposeConfirms the method measures what it claims to.
Measurement uncertaintyThe lab estimates the uncertainty of its resultsTells you how much a number could reasonably vary.
Proficiency testingThe lab’s results are compared with other labs on blind samplesShows its accuracy holds up over time.

For buyers

Why it matters

Reason 01

It is an outside check on the lab

Accreditation means someone independent has audited how the lab works, not just taken its word for it.

Reason 02

It makes results comparable

Traceable measurements and proficiency testing mean an accredited result can be compared with another lab’s.

Reason 03

The scope tells you what is covered

Reading the scope shows whether the specific test on a certificate was performed under the accreditation.

At Codex Research

Every Codex Research product page shows the lot-matched certificate for the lot in stock. If you want details of the testing laboratory and its accreditation for a specific lot, send the team the product and lot number.

See it live: the certificate of analysis guide in the glossary

Ask about a lot’s testing

Myth vs fact

Common misconceptions

Tap a card to flip it.

Watch for

Red flags in an accreditation claim

  • “ISO 17025 certified” with no accreditation body named
  • No accreditation certificate number provided
  • A scope of accreditation that does not include the test reported
  • An accreditation that has expired or been withdrawn
  • An accreditation body that is not an ILAC MRA signatory

Quick check

Checking a lab’s accreditation in 30 seconds

  1. 1Find the accreditation body

    And the lab’s certificate number.

  2. 2Read the scope

    The test you care about should be listed on it.

  3. 3Confirm it is current

    Accreditation bodies publish directories of accredited labs.

Full walkthrough · JournalThird-party testing and how to spot a fake COA

Questions

Frequently asked questions

What is ISO/IEC 17025?

The international standard for the competence of testing and calibration laboratories. Labs are accredited to it to show their results are technically valid.

What is the difference between ISO 17025 and ISO 9001?

ISO 9001 certifies a quality management system. ISO/IEC 17025 accreditation assesses whether a lab is technically competent to produce valid results for specific methods.

Who accredits labs to ISO/IEC 17025?

Accreditation bodies. In the US these include NIST’s NVLAP program and several private bodies. Many are signatories to the ILAC Mutual Recognition Arrangement.

What is a scope of accreditation?

The document listing the specific tests, sample types and methods a lab is accredited for. Accreditation only applies to what is on it.

How do I check if a lab is accredited?

Find the accreditation body and certificate number, then look the lab up in that body’s public directory and read its scope.

Is ISO 17025 required for research testing?

Not generally. It is voluntary for many labs, but an accredited result carries more weight because the lab has been independently assessed.

What is the current version of ISO/IEC 17025?

The 2017 edition, which replaced the 2005 version after a transition period.

Sources and standards

  1. ISO/IEC 17025:2017: General requirements for the competence of testing and calibration laboratoriesInternational Organization for Standardization
  2. ILAC Mutual Recognition Arrangement and SignatoriesInternational Laboratory Accreditation Cooperation
  3. National Voluntary Laboratory Accreditation Program (NVLAP)National Institute of Standards and Technology
  4. 15 CFR Part 285: National Voluntary Laboratory Accreditation ProgramElectronic Code of Federal Regulations

Written and reviewed by the Codex Research quality team · Last reviewed November 8, 2026 · For laboratory research use only.

On real products

Where this shows up

Every Codex product page publishes the certificate for the lot in stock. See ISO/IEC 17025 on a real product, then read the full guide.

CJC-1295 No DACGH axis

Research peptide

CJC-1295 No DAC

GH-Axis Research

CJC-1295 without DAC is modified GRF(1-29) carrying four substitutions at positions 2, 8, 15 and 27 that resist the plasma enzyme cutting native GHRH.

99%+Purity+174Reward pts
$69.99
View product
SermorelinGH axis

Research peptide

Sermorelin

GH-Axis Research

Sermorelin is GRF(1-29) amide, the shortest fragment of human GHRH that keeps full activity at the GHRH receptor, studied in pituitary and peptide-stability research.

99%+Purity+162Reward pts
$64.99
View product
GlutathioneCellular

Research peptide

Glutathione

Cellular Research

Glutathione is the gamma-linked tripeptide of glutamate, cysteine and glycine, the main low-molecular-weight thiol in aerobic cells, studied in redox biochemistry.

99%+Purity+124Reward pts
$49.99
View product
Journal guideThird-party testing and how to spot a fake COARead the guide

From lab to your door

Every compound.Every lot, proven.

U.S.-made research vials, shipped with lot-matched, lab-tested COAs you can scan straight off the label.